Expert Protection in Electric Arc and Molten Metal Hazards.

Two of the most destructive thermal threats in heavy industry: electric arc flash explosions reaching thousands of degrees within milliseconds, and incandescent 1400°C liquid metal splashes erupted from furnace ladles. Conventional flame-retardant workwear fails catastrophically under these conditions. Discover PPE engineered through rigorous fiber physics and certified by accredited test laboratories.

DISCIPLINE 01 IEC 61482 & ASTM F2675
ARC PLASMA // ~10,450°C – 20,000°C 125.3 cal HAND • 40 cal TORSO
ArSafe Glove and Arc Defender 40 Electric Arc Flash Protection Scene
Active System: ArSafe Glove + Arc Defender 40 APC 2 (7 kA)

Electric Arc Protection

Thermal defense against explosive plasma irradiation in switchgear, high-voltage substations, MCC cells, and power distribution systems. ArSafe glove with asymmetric dorsal shielding, Arc Defender 40 two-layer composite suit at only 440 g/m², and our first-party ArcSim incident energy simulation platform.

DISCIPLINE 02 ISO 9185 & EN ISO 11612
LADLE POURING // ~1400°C MOLTEN METAL ISO 9185 D3 / E3 • C2
Korgan Suit and Hood Molten Metal Splash Protection Scene
Active System: Korgan Suit & Hood + Molten Extreme D3 / E3 NON-STICK

Molten Metal Protection

Protection against liquid metal splashes in aluminium smelting, iron & steel foundries, and primary electrolysis baths. MARLAN PLUS architecture engineered with zero exterior aramid to completely eliminate molten metal adherence.

Precise Material Selection, Accredited Testing & Field Realities

In protective equipment engineering, vague superlative claims mean nothing; only physical truths and certified laboratory reports matter. The four pillars of our technical approach:

01

Physical Hazard Separation

The millisecond plasma radiance of an electric arc and the sticking physics of molten metal are distinct physical events. Aramid shields are deployed for arc flash; non-stick MARLAN PLUS systems for liquid metal.

02

Lightweight Ergonomics

Excessive fabric weight restricts mobility and triggers acute heat exhaustion. Arc Defender delivers 40 cal ELIM with 2 layers at only 440 g/m²; Korgan achieves D3/E3 at 350 g/m² for optimal operator dexterity.

03

Inherent Flame Retardancy

No chemical topical finishes (Proban etc.) that wash away over time. Flame resistance is engineered at the molecular polymer level. Korgan fabric retains its full certified protective matrix across 50 industrial wash cycles.

04

Verified Accredited Proof

Every specification is directly cross-referenced against official test report numbers from AITEX (0161) and Universal Certification (2163). No unsubstantiated numbers or unverified certificates are published.

4 Core Solutions, Certified Protection Levels

Each PPE solution engineered to the highest international standards within its operational risk envelope:

ArSafe Electric Arc Protective Glove
ARC PROTECTION

ArSafe Glove

Asymmetric thermal shield: 125.3 cal/cm² dorsal and 28.1 cal/cm² palmar ATPV thermal defense with APC 2 (7 kA) box test rating.

125.3 cal ATPV APC 2 ASTM F2675
Inspect ArSafe Details →
Arc Defender 40 Protective Jacket and Trousers
ARC PROTECTION

Arc Defender 40 Suit

Delivers 40 cal/cm² ELIM (49 cal/cm² Fabric ATPV) zero-burn threshold in an ultra-lightweight 440 g/m² (225 g/m² tear-resistant Ripstop outer shell + 215 g/m² thermal aramid inner liner) two-layer aramid composite system.

ELIM 40 / ATPV 49 cal 440 g/m² APC 2
Arc Defender Specifications →
Korgan Molten Metal Protective Suit and Hood
MOLTEN METAL PROTECTION

Korgan Suit & Hood

Jacket, trousers and detachable 350 g/m² hood. Non-stick inherent MARLAN PLUS architecture providing EN ISO 9185:2007 D3, E3 and >100g Cryolite protection.

D3 (≥350g Al) E3 (≥200g Fe) Cryolite
Inspect Korgan Details →
Molten Extreme Heavy Foundry Coat
MOLTEN METAL PROTECTION

Molten Extreme Coat

3-layer heavy foundry furnace coat (~615 g/m²). Features felt thermal barrier, C2 radiant heat resistance, and quick-release emergency closure.

C2 Radiant D3 / E3 Quick-Release
Molten Extreme Details →

Certified by European Notified Bodies

Our personal protective equipment is certified under the European Union PPE Regulation ((EU) 2016/425) Module B and Module D quality surveillance.

AITEX (0161) — Spain

Module B EU Type Examination, Open Arc (IEC 61482-1-1 / ASTM F2675), and Box Test (IEC 61482-1-2) accredited laboratory.

Universal (2163) — Turkey

Module D Production Quality Assurance approval. Rigorous surveillance of serial production batches against harmonized standards.

Industrial Washing & OEKO-TEX

Tested for 50 industrial wash cycles per EN ISO 15797, and certified skin-safe under OEKO-TEX® Standard 100.

1-Year Warranty & 3x Annual Field Audit

All protective garments include a 1-year manufacturing warranty plus 3x annual (every 4 months) on-site PPE field inspection & HSE reporting.

FULL-BODY ARC PPE ENSEMBLE INTEGRITY CHAIN

During high-energy switching operations, the Arc Defender 40 suit must be worn as a complete PPE ensemble: GS-ET-29 Class 2 arc flash hood/visor, EN 60903 dielectric insulating gloves + ArSafe APC 2 (ASTM F696) arc protector gloves, EN ISO 20345 safety boots, and a strict non-melting 100% Cotton / Natural FR Base Layer (zero polyester/nylon).

Frequently Asked Questions

What is the difference between arc flash protection and dielectric insulation? +

Dielectric gloves insulate against electric shock by blocking current flow through the body. Arc flash PPE protects against the extreme thermal plasma and radiant heat burst generated during an electrical arc fault.

Why is MARLAN PLUS preferred over aramid in molten metal environments? +

Aramid fibers chemically adhere to liquid molten metals, transferring dangerous heat directly to the skin. MARLAN PLUS (350 g/m²) generates a non-stick Leidenfrost vapor cushion in ISO 9185 tests, shedding molten metal in <1 s.

Which accredited testing bodies certified these protective systems? +

Our products are certified by accredited notified bodies including AITEX (0161) and Universal (2163) under EN IEC 61482-1-1, EN 61482-1-2, ASTM F2675, ISO 9185, and EN ISO 11612 standards.

Evaluate Your Operational Risk Envelope

Provide your substation voltage level, incident arc energy calculated via our ArcSim (arcsim.info/en/) platform, or smelted foundry alloy; our technical team will configure the compliant protective gear.

WhatsApp Quote